Prime Rating at rated rpm (as per ISO8528) |
kVA |
3 |
|
---|---|---|---|
Genset Model |
|
CC3SS |
|
Frequency |
Hz |
50 |
|
Power factor |
|
0.8 |
|
Voltage |
V |
230 |
|
Govering (As per ISO 8528 Part-V class) |
|
G2 |
|
Noise level |
|
≤ 70dbA |
|
Fuel Consumption* |
At 100% load |
Ltrs/Hr |
1.0 |
At 75% load |
0.75 |
||
At 50% load |
0.6 |
||
Fuel tank capacity |
Ltrs |
12.5 |
|
Overall dimensions of genset(L xW x H)^ |
|
920 x 560 x 920 |
|
Dry weight of genset with canopy ^ |
kg |
180 |
|
Wet weight of genset with canopy ^ |
kg |
190 |
|
Electrical Battery starting voltage |
Volts-Dc |
12 |
Engine Model |
|
CC306 G1 |
---|---|---|
Rated output(prime Continuous rating as per ISO 3046) |
Kw |
3 |
Hp |
4.08 |
|
NO. of cylinder |
Number |
1 |
Cubic capacity |
cc |
306 |
Rated Speed |
RPM |
3000 |
Aspiration |
|
NA |
Lube Oil change period |
Hrs |
200 |
Lube oil Sump Capacity |
Ltrs |
1.1 |
Insulation Class |
Class H |
---|---|
Altemator Efficiency (at 100% load) 0.8pf** |
74% |
Max Voltage Dip at full load 0.8 pf lag |
≤20% |
Max Time to build up rated voltage at rated RPM |
< 5 sec provided engine reach the rated speed |