EXTERNAL DIMENSION(LxWxH in mm): |
2750 X 1800 X 1850 |
|
INTERNAL DIMESNION(LxWxH in mm): |
2590 X 1640 X 1650 |
SIDE WALLS& END WALLS: |
1.5 MM GRP + 75 MM XPS + 1.5 MM GRP |
|
ROOF: |
1.5 MM GRP + 75 MM XPS + 1.5 MM GRP |
|
FLOOR: |
1.5 MM GRP + 75 MM XPS + 9 MM PLYWOOD + 1.5 MM GRP (Antislip) |
*-Tolerances apply
PARTICULAR |
DESCRIPTION |
---|---|
XPS |
*HIGHEST COMPRESSIVE STRENGTH(500Kpa),HIGHEST FLEXURAL STRENGTH(517Kpa),LOW THERMAL CONDUCTIVITY(0.0289W/m.K),LOW WATER ABSORPTION (0.3% VOLUME),HIGHEST STRENGTH TO WEIGHT RATIO |
BASE FRAME |
SHEET METAL Z SECTION 4 MM THK |
CONTAINER EXTERIOR SEALING |
OUTSIDE SEALING WILL BE DONE BY SPECIAL GRADE SEALANT |
EXTERNAL ANGLE |
SPECIALLY DESIGNED ALUMINIUM CORNER ANGLE |
KICK PLATE |
SIDE SKIRTING ALUMINUM PROFILE |
TOP LEAK PROOFING |
SPECIALIZED LEAKPROOF TAPE |
DOOR GASKET |
SPECIAL DESIGNED MULTI LEAF EPDM RUBBER |
MAIN DOOR |
METAL STRUCTURE DOOR |
DOOR FRAME |
GI SHEET METAL SECTION |
DOOR HARDWARE |
GI DOOR HARDWARE WITH DELTA HANDLE |
DRAINAGE |
1 NO DRAINAGE VALVE PROVIDED AT FRONT CO DRIVER SIDE |
REAR STEP |
STANDARD STEP PROVIDED WITH HANDLE TO EASY CLIMBING |
INTERNAL LIGHT |
LED LIGHT FLUSH TYPE WITH SUFFICIENT LUX LEVEL |
SIDE MARKER |
AS PER RTO NORMS |
REFLECTIVE TAPE |
RED AND YELLOW REFLECTIVE TAPE AS PER RTO NORMS |
LOADING LEVEL |
TAPE WILL BE PROVIDED |
REEFER UNIT MOUNITNG |
SUITABLE MOUNTING WILL BE PROVIDED |